Faculty Publications (Scholarly Results)
This is a list of the faculty staff’s knowledge-creation and scholarly output, including peer-reviewed research. Click on blue hyperlinks for full-text, or elsewhere in the grey box to view abstract. Padlock symbols 🔓 indicate Open Access.
2026 ▼
Mehran RABANI; Mehrdad RABANI (2026) “Numerical Investigation of the Thermal Performance of a PCM-Filled Glazing Cavity in a Trombe Wall System”🔓. Buildings, Vol.16, Art.3497 (no.17) …
Abstract: Trombe walls are widely used passive solar heating systems for cold winter climates, but suffer from large diurnal temperature swings and limited heat delivery after sunset. This study numerically investigates replacing the air in the double-glazing gap of a Trombe wall with a phase change material (PCM). A two-dimensional transient CFD model of a 4 m × 3 m room with a Trombe wall was developed in ANSYS Fluent using the enthalpy porosity method and the realizable k–ε turbulence model. Grid independence was confirmed with a 36,000-cell mesh, and the air-filled reference case was validated against published Trombe wall data within 9%. Hourly ambient temperature and solar heat flux records for a recent cold, clear winter day in Yazd, Iran, were imposed as boundary conditions. The PCM-filled cavity was cooler than the air-filled case shortly after sunrise, by about 1–1.6 °C, as the PCM resumed absorbing heat after releasing its reserve overnight. The two configurations converged around midday, after which the PCM-filled cavity became progressively warmer, reaching a margin of 4–6 °C in the early evening, and easing somewhat overnight while remaining the warmer of the two. The PCM-filled cavity also drove higher buoyancy induced velocities. The PCM layer’s nominal storage capacity was about 9.4 MJ per meter of wall length, over four orders of magnitude more than air, 89% as latent heat. Mean room temperature rose by 1.1 °C; the standard deviation and peak-to-peak swing increased accordingly, and time within the 20–26 °C comfort band fell from 59.8% to 47.0%, reflecting heat concentrated in the evening rather than spread evenly. Overall, the PCM-filled cavity increases heat availability specifically after sunset, when heating demand is greatest, rather than producing a general improvement in steady state thermal comfort, and does so without additional energy input.
Permalink: https://doi.org/10.3390/buildings16173497
Permalink: https://doi.org/10.3390/buildings16173497
Lars Ø. RASTAD, Arnab CHAUDHURI, Habtamu B. MADESSA (2026) “Model predictive control in real-world buildings – a systematic review of implementation and performance”🔓. Sustainable Energy Technologies and Assessments, Vol.91, p.105034-105034 …
Abstract: This paper investigates the application of Model Predictive Control (MPC) for optimisation of building operation, with a focus on implementation and scalability. A systematic review was conducted to categorise MPC application areas and prediction models, identify key challenges and limitations, and evaluate the overall performance reported for MPC. The results show that MPC implementations vary considerably with respect to adopted methodology, climatic conditions and control objectives. Reported energy savings range from a few per cent up to 56.3%, while cost savings reach up to 55%. MPC applications are most prevalent in hydronic heating systems due to their flexibility in integrating multiple energy sources. In smart-city contexts, MPC supports energy efficient design and on-site renewable energy generation by improving self-consumption and enabling load shifting. Grey-box models are the most widely used modelling approach, accounting for 62% of implementations overall and 86% in residential single-family buildings, where IoT devices and smart sensors are frequently utilised. Despite these advances, limited commercialisation remains a key barrier, highlighting the need for further research on scalable deployment and market adoption.
Permalink: https://doi.org/10.1016/j.seta.2026.105034
Permalink: https://doi.org/10.1016/j.seta.2026.105034
Lars Ø. RASTAD, Arnab CHAUDHURI, Habtamu B. MADESSA (2026) “Predictive Control in Buildings—A Commercializing View of the Norwegian Building Industry”. in I. MARTINAC, B.N. JØRGENSEN, Z. MA, R. UNNÞÓRSSON, C. BORDIN, Energy Informatics, Springer, p.269-286 …
Abstract: This study investigates the adoption of predictive control methods in the Norwegian building industry, focusing on their current usage and the gap between academic research and industry practices. A survey of 59 companies, with a 54.2% response rate, revealed that 75% of participants use predictive control methods beyond outdoor temperature compensation, with 54% employing them regularly. Results show that the methods are predominantly applied to heating, cooling, and ventilation systems, with heating being the most common. While predictive control methods are widely adopted, advanced strategies like Model Predictive Control (MPC) remain underutilized. Only 9.3% of participants reported using MPC, and just 34.4% were familiar with it. This highlights a significant gap between academic advancements and industry implementation. Most predictive control methods integrate with existing infrastructures by adjusting PI/PID controller setpoints, reflecting a practical approach to innovation. The study concludes that while predictive control methods are gaining traction, significant potential remains untapped. Bridging the gap between research and practice requires targeted outreach, education, and practical demonstrations to accelerate the adoption of advanced control strategies, ultimately fostering sustainable and efficient building operations.
Permalink: https://doi.org/10.1007/978-3-032-19137-3_18
Permalink: https://doi.org/10.1007/978-3-032-19137-3_18
Yngve Øye FREMMERLID; Moon K. KIM (2026) “Forecasting Electricity Consumption Using Artificial Neural Networks (ANNs): The Impact of Weather Conditions”. in C. ZILIO, F. BUSATO, L. MAZZARELLA, M. NORO, Proceedings of the 15th REHVA HVAC World Congress CLIMA 2025, Springer Nature, p.446-458 …
Abstract: This study investigates the application of artificial neural networks (ANNs) for forecasting electricity usage in buildings, taking into account meteorological conditions and electricity pricing. Two feedforward artificial neural network models are utilized, employing the Levenberg-Marquardt and Quasi-Newton back propagation methods. The networks, designed with diverse depths and widths, are entirely interconnected. The primary objectives of the study are: (1) to develop and compare two predictive models, (2) to analyze the effects of various architectures, algorithms, and data processing techniques on model performance, and (3) to perform sensitivity analysis to evaluate the impact of input variables, including weather conditions. Empirical data from the Norwegian Maritime Museum underpins model training and validation. The results indicate that ANN models show potential in forecasting electricity usage trends, with performance differing according to the backpropagation algorithm, network architecture, and preprocessing techniques. Although the models accurately reflect consumption trends, they exhibit a deficiency in numerical precision, frequently diverging in absolute amounts. Sensitivity analysis identifies solar irradiance and electricity costs as key predictors, although ambient temperature significantly affects consumption during occupied hours. The results indicate that integrating meteorological and pricing information into predictive models can enhance the regulation of electricity consumption in structures. It is advisable to do additional study to incorporate supplementary factors and optimize ANN structures to improve predictive accuracy.
Permalink: https://doi.org/10.1007/978-3-032-10546-2_42
Permalink: https://doi.org/10.1007/978-3-032-10546-2_42
Amar AGANOVIC; Espen Aufles HANSEN; Christoffer Bang HEMMINGSEN; Džana KADRIĆ; Mehrdad RABANI, Ajdin VATREŠ; Edin KADRIĆ (2026) “Target-based multi-objective retrofit design of nZEB school buildings using room-specific indoor environmental quality requirements”🔓. Building and Environment, Vol.296, Art.114546 …
Abstract: Retrofit design for nearly zero emission (nZEB) school buildings must reconcile strict energy targets with healthy, comfortable indoor environments. Most multi-objective retrofit studies either model a single representative zone or optimise building-average indicators, which can mask rooms with poor indoor air quality (IAQ) or thermal comfort. In a Norwegian agricultural school, baseline simulations show that building-average CO2 and predicted percentage dissatisfied (PPD) meet common design targets, while several rooms exceed IAQ and comfort thresholds.We propose a target-based multi-objective optimisation framework that explicitly constrains the worst-performing rooms. Four objectives are considered: annual specific energy use, maximum room CO2, maximum room PPD, and total retrofit investment cost. Energy use is constrained to the Norwegian nZEB limit for schools (≤ 91 kWh/(m2·y)), with CO2 and PPD limited to 800 ppm and 10 %, in line with EN 16798 and recent IAQ guidance. Eight design variables (envelope U-values, supply-air temperature setpoints, infiltration, and ventilation rates) are explored using a Definitive Screening Design with 17 IDA-ICE simulations and second-order surrogate models (R2 ≥ 0.99). These feed an NSGA-III algorithm to generate a Pareto front, which is post-processed with an Entropy–TOPSIS method to rank solutions. Results show that retrofit strategies can keep every room below 800 ppm CO2 and 10 % PPD while satisfying the nZEB energy limit at moderate investment levels. The framework is generic and transferable, providing transparent decision support that shifts from building-average metrics toward room-specific occupant protection.
Permalink: https://doi.org/10.1016/j.buildenv.2026.114546
Permalink: https://doi.org/10.1016/j.buildenv.2026.114546
Lasse Bækdal AHRENDSEN; Sara Moukhaiber ASKLAND; Chen ZHANG; Simon Pommerencke MELGAARD; Arnkell Jonas PETERSEN; Mehrdad RABANI, Per Kvols HEISELBERG (2026) “Monte Carlo Simulations and Sensitivity Analysis for Developing Control Strategies in Hybrid Ventilation Systems”🔓. Energy and Buildings, Vol.359, Art.117294, p.1-18 …
Abstract: Hybrid ventilation hold substantial potential for minimising energy use while maintaining acceptable indoor air quality and thermal comfort, yet developing effective control strategies is challenging because many variables interact and objectives conflict. Widely used heuristics (rule-based, fuzzy logic) are simple but inflexible; optimal approaches (Model Predictive Control, Reinforcement Learning) need extensive high-quality data that are rarely available in early design. This study proposes a Monte-Carlo framework that couples global and local sensitivity analysis with multi-criteria decision-making to develop hybrid ventilation control strategies from limited early-stage information. A generic Oslo office building with three room types (open-plan office, conference room, cell office) serves as the case study. Inputs such as temperature setpoints, airflow rates, night ventilation schedules, are sampled within stakeholder-defined ranges; 10000 simulations per room map the control space. Sensitivity analysis identifies mechanical ventilation airflow as the dominant driver of energy use, indoor air quality and thermal comfort metrics across all rooms. Interactive parallel coordinates plots with real-time sensitivity feedback allow stakeholders to filter and explore solutions, visualise trade-offs and converge on a small set of high-performing strategies. Imposing a single supply air temperature for all rooms worsens the cell office weighted score by 5 /cent to 12 /cent, quantifying the trade-off of a centralised air handling unit constraint. The framework delivers a structured yet flexible method, requiring only envelope data and broad setpoint ranges. It can be rerun as design evolves, providing consultants with a transparent alternative to rule-of-thumb tuning or data reliant optimal control methods.
Permalink: https://doi.org/10.1016/j.enbuild.2026.117294
Permalink: https://doi.org/10.1016/j.enbuild.2026.117294